Skip to main content

Table 4 Multivariable logistic regression analysis of risk factors measured at H6 for MOF death

From: Toe-to-room temperature gradient correlates with tissue perfusion and predicts outcome in selected critically ill patients with severe infections

 

Crude OR (95 % CI)

Adjusted OR (95 % CI)

P

Toe-to-room temperature gradient

Per additional degree Celsius

0.7 [0.6, 0.9]

0.7 [0.5, 0.9]

<0.001

SOFA score

Per additional point

1.4 [1.2, 1.6]

1.5 [1.2, 1.8]

<0.001

Malignancy

Yes versus no

2.4 [0.9, 6.3]

4.3 [1.1, 16.7]

0.03