Table 4 Results from individual studies of neutrophil CD64 and C-reactive protein as markers for the diagnosis of sepsis

From: Comparison of the accuracy of neutrophil CD64, procalcitonin, and C-reactive protein for sepsis identification: a systematic review and meta-analysis

References

Sepsis/control (n)

Neutrophil CD64

C-reactive protein

Sensitivity

Specificity

AUC

Sensitivity

Specificity

AUC

Davis et al. [18]

38/62

0.88

0.71

–

0.88

0.59

–

Dimoula et al. [26]

103/365

0.89

0.87

0.94

0.84

0.86

0.92

Righi et al. [27]

61/32

0.90

0.97

0.93

0.89

0.41

0.71

Godnic et al. [28]

40/7

0.76

0.75

0.83

0.77

0.75

0.73

Bauer et al. [29]

110/86

0.76

0.77

0.83

0.77

0.77

0.86

Muzlovic et al. [30]

25/7

1.00

0.86

0.93

0.83

0.86

0.87

Total

377/559

0.84 (95% CI 0.76–0.89)

0.81 (95% CI 0.73–0.87)

0.89 (95% CI 0.87–0.92)

0.83 (95% CI 0.78–0.86)

0.71 (95% CI 0.56–0.85)

0.84 (95% CI 0.80–0.88)