Skip to main content

Table 3 Changes in measurements of coagulation over duration of treatment

From: Effects of regional citrate anticoagulation on thrombin generation, fibrinolysis and platelet function in critically ill patients receiving continuous renal replacement therapy for acute kidney injury: a prospective study

 

Baseline

12 h

24 h

36 h

48 h

72 h

p value*

Haemoglobin (g/L)

102 (28)

95 (26)

93 (23)

91 (25)

91 (17)

87 (19)

0.017

Haematocrit

0.32 (0.09)

0.29 (0.08)

0.29 (0.07)

0.28 (0.08)

0.28 (0.06)

0.27 (0.06)

 

Platelets (× 109/L)

233 (164)

187 (114)

176 (104)

173 (107)

174 (110)

169 (95)

0.043

INR

 Systemic

1.18 (0.15)

1.13 (0.13)

1.13 (0.13)

1.10 (0.11)

1.08 (0.10)

1.06 (0.09)

0.018

 Circuit

 

1.22 (0.15)

1.15 (0.13)

1.13 (0.11)

1.10 (0.10)

1.08 (0.12)

0.020

APTTr

 Systemic

1.29 (0.31)

1.25 (0.37)

1.18 (0.20)

1.11 (0.21)

1.11 (0.18)

1.17 (0.30)

0.077

 Circuit

 

1.33 (0.38)

1.23 (0.24)

1.17 (0.22)

1.20 (0.24)

1.19 (0.28)

0.262

Fibrinogen (g/L)

 Systemic

4.81 (1.47)

5.01 (1.67)

5.53 (1.85)

5.25 (1.74)

5.36 (1.64)

5.13 (1.80)

0.868

 Circuit

 

5.12 (1.70)

5.27 (2.07)

5.33 (1.86)

5.42 (1.58)

5.31 (1.93)

0.309

D-Dimer (mg/L)

 Systemic

15.8 (15.9)

13.4 (11.8)

16.2 (9.3)

14.4 (9.2)

13.8 (12.8)

15.5 (14.5)

0.984

 Circuit

 

15.4 (13.1)

15.2 (9.3)

13.4 (9.2)

15.1 (14.1)

15.6 (13.9)

0.912

TGA: maximum thrombin generation (nM)**

 Systemic

498.5 (390.6)

650.2 (383.8)

631.5 (397.7)

649.9 (443.9)

599.3 (290.3)

557.3 (315.1)

0.948

 Circuit

 

606.4 (422.9)

612.2 (349.7)

678.9 (458.3)

670.8 (249.0)

603.5 (187.6)

0.642

TGA: time to peak thrombin generation (min)**

 Systemic

22.9 (10.5)

21.5 (11.2)

26.3 (10.4)

21.7 (8.1)

28.7 (12.4)

31.1 (14.0)

0.186

 Circuit

 

22.7 (11.3)

27.6 (10.7)

21.3 (6.5)

23.2 (12.1)

25.9 (6.5)

0.668

PFSCA CT (s)***

 Systemic

127(80)

162 (92)

137 (82)

130 (45)

139 (84)

123 (74)

0.694

 Circuit

 

166 (94)

145 (72)

216 (84)

169 (89)

148 (74)

0.126

PFSCE CT (s)****

 Systemic

140 (85)

160 (77)

159 (75)

198 (69)

138 (36)

155 (73)

0.200

 Circuit

 

176 (87)

170 (82)

169 (80)

162 (64)

175 (68)

0.970

  1. INR International Normalised Ratio, APTTr activated partial thromboplastin time ratio, TGA thrombin generation assay, PFSCA platelet function assay using collagen/adenosine diphosphate, PFSCE platelet function assay using collagen/epinephrine, CT closure time
  2. *Repeated measures ANOVAs compared systemic parameters from baseline to 48 h. Post hoc pairwise comparisons found significant differences between haemoglobin at baseline and 36 h (p = 0.030) and baseline and 48 h (p = 0.018); platelets at baseline and 36 h (p = 0.035) and baseline and 48 h (p = 0.040) and INR at baseline and 36 h (p = 0.034) and baseline and 48 h (p = 0.024). There were no significant differences in systemic parameters on CRRT. Repeated measures ANOVAs of measurements from the circuit compared data from 12 to 48 h. Only INR differed overtime, with a significant difference between 12 and 48 h in post hoc comparisons (p = 0.002)
  3. **Test failed to return a result in 6.8% of samples (8/117)
  4. ***Test exceeded maximum permitted duration in 25.6% of samples (30/117); lower bound for duration of 300 s was used in analysis
  5. ****Test exceeded maximum permitted duration in 27.4% of samples (32/117), lower bound for duration of 300 s was used in analysis