Skip to main content

Table 2 Reporting of ECMO-related outcomes and complication rate

From: Extracorporeal membrane oxygenation for cardiogenic shock: a meta-analysis of mortality and complications

Outcome

Number of studies reporting data (events/population)

Pooled rate (95%CI)

I2 (p value)

Reported range (%)

Mortality

 Brain death

4 (154/1042)

13.1 (9.4; 17.8)

65% (0.035)

7.6–16.6

 Death during ECMO

14 (2909/7783)

42.9 (38.3; 47.7)

91% (< 0.001)

33.4–53.5

 In-hospital mortality

32 (8493/12756)

62.2 (58.8; 65.5)

92% (< 0.001)

40.3–75.2

Stroke

 CNS complications (not specified)

7 (360/2450)

12.5 (13.9; 16.8)

82% (< 0.001)

5.4–19.1

 Cerebral bleeding/hemorrhagic stroke

12 (263/3969)

5.6 (3.4; 9.0)

92% (< 0.001)

2.7–25.4

 Ischemic stroke

13 (414/4371)

9.8 (7.2; 13.1)

89% (< 0.001)

1.4–26.9

 Stroke (not otherwise specified)

10 (206/2704)

8.6 (5.3; 13.5)

91% (< 0.001)

2.3–25.5

Renal failure

 Renal failure

7 (693/1351)

50.5 (31.7; 69.2)

97% (< 0.001)

9.5–85.7

 Renal replacement therapy

23 (4879/11186)

44.3 (39.2; 49.5)

96% (< 0.001)

10.3–70.5

Infections

 Infection (not otherwise specified)

4 (290/1395)

18.8 (14.3; 24.2)

80% (0.002)

13.0–24.7

 Pneumonia

8 (617/2298)

23.7 (16.2; 33.3)

95% (< 0.001)

7.9–61.0

 Sepsis

9 (489/2529)

17.8 (14.3; 21.9)

83% (< 0.001)

6.4–28.2

 MODS

3 (171/584)

24.4 (13.3; 40.4)

93% (< 0.001)

8.9–37.3

Bleeding

 Any bleeding

15 (1971/4523)

48.5 (40.6; 56.4)

96% (< 0.001)

17.8–97.0

 Surgical site bleeding

2 (66/390)

14.9 (3.7; 44.4)

96% (< 0.001)

7.4–27.3

 Cannulation site bleeding

8 (224/1464)

16.8 (11.1; 24.7)

91% (< 0.001)

3.9–28.4

 Gastrointestinal bleeding

6 (74/1335)

5.9 (3.3; 10.5)

84% (< 0.001)

0.9–12.3

 Cardiac tamponade

3 (42/406)

10.5 (7.9; 13.9)

0% (0.423)

8.4–12.7

 Pulmonary hemorrhage

2 (24/305)

8.4 (3.5; 18.7)

79% (0.029)

5.4–12.7

 Disseminated intravascular coagulation

1 (26/148)

–

–

–

 Hemolysis

1 (6/462)

–

–

–

Thrombosis

 Any thrombosis

5 (187/921)

13.4 (6.7; 25.1)

93% (< 0.001)

2.0–34.0

 Limb ischemia

23 (868/5932)

12.2 (8.7; 16.9)

96% (< 0.001)

3.7–43.9

 Limb amputation

5 (19/1368)

1.5 (1.0; 2.3)

0% (0.733)

0.4–1.9

 Arterial thrombosis

1 (63/344)

–

–

–

 Venous thrombosis

1 (11/344)

–

–

–

 Pulmonary embolism

1 (3/203)

–

–

–

Mechanical complications

 Circuit component clots

3 (12/771)

1.8 (0.5; 6.7)

81% (0.006)

0.9–5.7

 Oxygenator replacements

4 (111/1253)

9.0 (3.7; 20.3)

92% (< 0.001)

0.0–25.6

  1. ECMO Extracorporeal membrane oxygenation, CNS Central nervous system, MODS Multiple organ dysfunction syndrome