Skip to main content

Table 2 ROX index accuracy to predict HFNO failure at different times after HFNO initiation

From: ROX index performance to predict high-flow nasal oxygen outcome in Covid-19 related hypoxemic acute respiratory failure

Time after HFNO initiation

Maximum of Youden’s index

Rox index cut-off

Sensitivity*

95% CI limits for sensitivity

Specificity

95% CI limits for specificity

AUROC

Lower

Upper

Lower

Upper

H0

0.393

6.20

63.3%

48.3%

76.6%

76.0%

61.8%

86.9%

0.70

H2-H4

0.413

6.88

78.0%

62.4%

89.4%

63.3%

48.3%

76.6%

0.71

H6

0.361

7.00

75.7%

58.8%

88.2%

60.4%

45.3%

74.2%

0.68

H12

0.320

8.73

87.1%

70.2%

96.4%

44.9%

30.7%

59.8%

0.66

H18

0.398

6.96

69.0%

49.2%

84.7%

70.8%

55.9%

83.0%

0.70

H24

0.490

6.96

77.3%

54.6%

92.2%

71.7%

56.5%

84.0%

0.75

H48

0.343

5.00

43.8%

19.8%

70.1%

90.5%

77.4%

97.3%

0.67

H72

0.543

5.78

80.0%

44.4%

97.5%

74.3%

56.7%

87.5%

0.77

  1. HFNO high-flow nasal oxygen therapy, AUROC area under the receiver operating characteristic curve, CI confidence interval; * = proportion of patients with ROX index ≤ cut-off among those who failed HFNO within 28 days after ICU admission