Skip to main content

Table 6 Summary diagnostic accuracy of the included studies for biomarkers, presepsin, procalcitonin, and C-reactive protein

From: Comparison of diagnostic accuracy in sepsis between presepsin, procalcitonin, and C-reactive protein: a systematic review and meta-analysis

References

Sepsis/control (n)

Presepsin

Procalcitonin

C-reactive protein

Sensitivity

Specificity

AUC

Sensitivity

Specificity

AUC

Sensitivity

Specificity

AUC

Shozushima et al. [17]

101/41

0.80

0.81

0.88

–

–

0.65

–

–

0.82

Endo et al. [29]

115/70

0.88

0.81

0.91

0.86

0.79

0.91

–

–

–

Liu et al. [33]

680/279

0.71

0.86

0.82

0.60

0.78

0.72

–

–

–

Ulla et al. [38]

106/83

0.79

0.62

0.70

0.89

0.76

0.88

–

–

–

Vodnik et al. [39]

30/100

1

0.98

0.99

0.87

0.97

0.96

–

–

0.96

Behnes et al. [25]

81/15

0.90

0.60

0.84

–

–

0.86

–

–

–

Brenner et al. [26]

60/60

0.91

0.67

0.83

0.77

0.78

0.84

0.67

0.85

0.79

Romualdo et al. [35]

37/189

0.81

0.63

0.75

0.76

0.64

0.79

0.62

0.52

0.60

Ishikura et al. [31]

43/39

0.93

0.76

0.89

–

–

–

–

–

–

Kweon et al. [32]

73/45

0.88

0.82

0.94

0.86

0.87

0.92

0.99

0.67

0.85

Cakir Madenci et al. [27]

26/11

0.77

0.76

0.83

0.76

0.79

0.85

0.92

0.58

0.82

Nakamura et al. [34]

37/75

0.70

0.81

0.78

–

–

–

–

–

–

Sargentini et al. [36]

60/44

0.86

0.72

0.89

0.80

0.80

0.91

–

–

–

Godnic et al. [30]

40/7

0.85

0.63

0.71

0.58

0.67

0.63

0.77

0.75

0.73

Takahashi et al. [37]

359/97

0.80

0.83

0.89

0.77

0.76

0.85

0.72

0.95

0.82

Carpio et al. [28]

114/9

0.81

0.75

0.83

–

–

–

–

–

–

Kada Klouche et al. [41]

100/44

0.90

0.55

0.75

0.80

0.59

0.80

–

–

–

Romualdo et al. [40]

70/130

0.67

0.81

0.78

0.67

0.84

0.82

0.26

0.92

0.59