Skip to main content

Table 1 EKG recording before and after transesophageal electric pacing

From: Proceedings of Réanimation 2020, the French Intensive Care Society International Congress

 

Sham (n = 10)

Septic (n = 10)

Septic + landiolol (n = 10)

EKG recording before transesophageal stimulation

   

 Heart rate (bpm), mean ± SD

362 ± 27

502 ± 30

465 ± 21

 Sinus cycle length (ms), mean ± SD

167 ± 12

118 ± 9

130 ± 7

 P wave (ms), mean ± SD

11 ± 2

17 ± 2

8 ± 2

 PR interval (ms), mean ± SD

40 ± 5

43 ± 6

42 ± 5

 QRS duration (ms), mean ± SD

10 ± 1

9 ± 1

9 ± 1

 QT interval (ms), mean ± SD

15 ± 2

15 ± 2

15 ± 3

 QTc (ms), mean ± SD

37 ± 4

43 ± 8

40 ± 13

EKG recording after transesophageal stimulation

   

 Atrial fibrillation, n (%)

0 (0%)

7 (70%)

2 (20%)