Assessing left ventricular systolic function with ejection fraction: using a double-edged knife as a hammer

A Letter to the Editor Response to this article was published on 02 October 2019

The Original Article was published on 30 May 2019


Dear Editor,

We have read with interest the paper about the potential limitations of arterial dP/dtmax for assessing left ventricular (LV) contractility [1]. In this study, the authors aimed to evaluate the performance of femoral dP/dtmax from tracking changes in LV systolic function during different therapeutic interventions. They have studied 19 patients with circulatory shock and concluded that femoral dP/dtmax was an unreliable estimate of LV systolic function as it was markedly affected by arterial load, particularly during changes in norepinephrine dose.

As the authors have mentioned our recent study about this specific topic [2], we would like to highlight some potential issues that we believe should be considered when interpreting their results.

First and most important, the use of LV ejection fraction (LVEF) as a marker of LV systolic function. As the authors themselves declared, LVEF cannot be considered as a pure marker of LV systolic function, as it is also greatly influenced by the afterload conditions [3]. In this regard, we have recently published a detailed analysis of the effects of different loading and contractile conditions on LVEF [4]. In that study, we showed that LVEF poorly tracked LV contractility changes when using LV end-systolic elastance (Ees) as a load-independent measure of cardiac contractility [5], especially when afterload was altered.

To demonstrate the potential impact of this phenomenon on the current study, we have performed a concordance analysis using data from our previous study (Fig. 1) [2]. These four-quadrant plots represent the agreement in the directional change of the variations of two variables. The upper plot represents the agreement in LVEF and LV contractility, as assessed by Ees. The graph in middle shows the agreement between femoral dP/dtmax and Ees. And the last one, the concordance between femoral dP/dtmax and LVEF, just as the authors have performed in the current study. It is clear from this analysis that LVEF was a poor index of LV contractility during changes in afterload conditions (upper plot), as LVEF changes in the opposite direction to variations in LV contractility. However, femoral dP/dtmax was able to track contractility changes during afterload interventions (middle plot), even if changes in arterial load conditions could potentially affect femoral dP/dtmax. Finally, comparing femoral dP/dtmax against LVEF, i.e., reproducing the author’s hypothesis and methodology, only proved that LVEF was unable to track changes in LV contractility when afterload was primarily affected. So, the use of LVEF as a surrogate for defining LV systolic function in the current study could explain the discrepancies with our previous results, which were based on a load-independent measure of contractility such as the LV end-systolic elastance. Therefore, for a physiological study aimed at evaluating LV contractility, the use of LVEF cannot be recommended.

Fig. 1
figure 1

Concordance analysis. Four-quadrant plots showing the relationship between the percentage changes in left ventricular ejection fraction (LVEF) and left ventricular end-systolic elastance (Ees) (upper plot), femoral dP/dtmax and Ees (middle plot), and femoral dP/dtmax and LVEF (lower plot). Excellent trending capability is considered when ≥ 90% of the points lie in the right-upper and left-lower quadrants

So, unfortunately, although we acknowledge that evaluating LV contractility at the bedside is not an easy task, we believe that the current study could be weakened by this methodological assumption. As our previous study demonstrated, femoral dP/dtmax was able to track contractility changes even if the intervention was primarily to alter arterial tone or contractility varied. Since femoral dP/dtmax is readily available from the femoral arterial waveform, this information is clinically valuable.

Availability of data and materials

The data that support the findings of this study are available from the corresponding author upon reasonable request.

References

  1. Vaquer S, Chemla D, Teboul JL, Ahmad U, Cipriani F, Oliva JC, Ochagavia A, Artigas A, Baigorri F, Monnet X. Influence of changes in ventricular systolic function and loading conditions on pulse contour analysis-derived femoral dP/dt max. Ann Intensive Care. 2019;9(1):61.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Monge Garcia MI, Jian Z, Settels JJ, Hunley C, Cecconi M, Hatib F, Pinsky MR. Performance comparison of ventricular and arterial dP/dt max for assessing left ventricular systolic function during different experimental loading and contractile conditions. Crit Care. 2018;22(1):325.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Robotham JL, Takata M, Berman M, Harasawa Y. Ejection fraction revisited. Anesthesiology. 1991;74(1):172–83.

    Article  CAS  PubMed  Google Scholar 

  4. Monge Garcia MI, Jian Z, Settels JJ, Hunley C, Cecconi M, Hatib F, Pinsky MR. Determinants of left ventricular ejection fraction and a novel method to improve its assessment of myocardial contractility. Ann Intensive Care. 2019;9(1):48.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Walley KR. Left ventricular function: time-varying elastance and left ventricular aortic coupling. Crit Care. 2016;20:270.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

None.

Author information

Authors and Affiliations

Authors

Contributions

MIMG, MC and MRP were responsible for drafting and the critical revision of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to M. Ignacio Monge García.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Monge García, M.I., Cecconi, M. & Pinsky, M.R. Assessing left ventricular systolic function with ejection fraction: using a double-edged knife as a hammer. Ann. Intensive Care 9, 111 (2019). https://doi.org/10.1186/s13613-019-0582-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13613-019-0582-z