Dear Editor,

We thank Beyls and colleagues for their interest in our recent article on left atrial strain (LAS) [1]. They stated that our sample size calculation, based on a predicted 5% increase in the LAS reservoir (LASr), might be underestimated given that the repeatability and reliability of the LAS measurement is unknown. As stated in the Methods section of our paper, we attempted to minimise measurement inconsistencies. First, we used Automated Function Imaging (AFI) left atrial software (EchoPAC, GE Healthcare), which follows the 2018 EACVI-ASE Strain Standardised Task Force guidelines [2]. Second, we performed LAS analysis according to the cited recommendations [2], including measurement of left atrial strain in both four-chamber and two-chamber apical views. The same methodology has been used in large studies that have helped to define reference values for LAS [3]. Third, we assessed intra-observer variability in 10 randomly selected subjects using the interclass correlation coefficient (ICC), a measure of repeatability according to the study by Bunting et al. [4]. In our cohort, intra-observer analysis showed good repeatability of the three components of left atrial strain: LASr (ICC = 0.92), LAS conduit (LAScd) (ICC = 0.81), LAS contraction (LASct) (ICC = 0.95). Finally, we performed intra- and inter-observer variability analysis according to the methods of previous studies, including the paper by Beyls et al. [5], which investigated LAS as a predictive marker of atrial fibrillation (AF) in patients with COVID-19 pneumonia.

Beyls et al. mentioned that the value of the LASr we identified for sample size calculation was derived from previous studies using different software for LAS analysis and that there is some evidence of inter-vendor variability in strain measurements. They cited the study by Wang et al. [6] comparing EchoPAC version 201 (GE Vingmed Ultrasound) and Image Arena 2D Cardiac Performance Analysis version 4.6 (TomTec Imaging Systems, Unterschleissheim, Germany). However, in the paper by Wang et al. [6], the EchoPAC system used the LV strain package to assess LAS, as did many other studies prior to the commercialisation of the AFI left atrial software. To our knowledge, there are no published studies comparing EchoPAC AFI left atrial and TomTec.

The authors correctly mentioned that assessing fluid responsiveness by Left Ventricular Outflow Tract – Velocity Time Integral (LVOT – VTI) variation may have led to misclassification of patients. We agree that this is a limitation of our work and have already discussed this in the Limitations section of the article. The observational nature of our study necessitated the use of echocardiography to estimate cardiac output, as haemodynamic monitoring is routinely performed by echocardiography in our ICU. Regarding the observed improvement in haemodynamics in the non-responder group, although the increase in arterial pressure during volume expansion was statistically significant, its clinical relevance is questionable.

The authors highlight that we studied a heterogeneous cohort of patients with varying degrees of pre-existing left atrial dysfunction prior to ICU admission; this may have influenced the LAS response to fluid administration. We agree that cardiac comorbidities may affect atrial function in the acute setting and influence treatment response. However, it is difficult to investigate the contribution of pre-admission pathology because baseline echocardiography is not always available and rarely includes left atrial strain measurement. We tested the two groups (fluid responders and non-responders) for differences in comorbidities and there was no significant difference (unpublished). From a pragmatic perspective, as chronic cardiovascular disease is common in critically ill patients, we believe that our cohort reflects the routine practice ICU population.

In conclusion, we agree that further studies are needed to investigate the usefulness of LAS in critically ill patients.

Data availability

Not applicable.

Abbreviations

LAS:

Left Atrial Strain

LASr:

Left Atrial Strain reservoir

AFI:

Automated Function Imaging

EACVI:

European Association of CadioVascular Imaging

ASE:

American Society of Echocardiography

LAScd:

LAS conduit

LASct:

LAS contraction

AF:

Atrial Fibrillation

LVOT – VTI:

Left Ventricular Outflow Tract – Velocity Time Integral

ICU:

Intensive Care Unit

References

  1. Cicetti M, Bagate F, Lapenta C, Gendreau S, Masi P, Mekontso Dessap A. Effect of volume infusion on left atrial strain in acute circulatory failure. Ann Intensive Care. 2024;14(1):53. https://doi.org/10.1186/s13613-024-01274-6. PMID: 38592568; PMCID: PMC11003961.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  2. Badano LP, Kolias TJ, Muraru D, Abraham TP, Aurigemma G, Edvardsen T, D’Hooge J, Donal E, Fraser AG, Marwick T, Mertens L, Popescu BA, Sengupta PP, Lancellotti P, Thomas JD, Voigt JU. Industry representatives; Reviewers: This document was reviewed by members of the 2016–2018 EACVI Scientific Documents Committee. Standardization of left atrial, right ventricular, and right atrial deformation imaging using two-dimensional speckle tracking echocardiography: a consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging. Eur Heart J Cardiovasc Imaging. 2018;19(6):591–600. https://doi.org/10.1093/ehjci/jey042. Erratum in: Eur Heart J Cardiovasc Imaging. 2018;19(7):830–833. PMID: 29596561.

  3. Tadafumi Sugimoto S, Robinet R, Dulgheru, et al. Echocardiographic reference ranges for normal left atrial function parameters: results from the EACVI NORRE study. Eur Heart J - Cardiovasc Imaging. 2018;19:630–8. https://doi.org/10.1093/ehjci/jey018.

    Article  PubMed  Google Scholar 

  4. Bunting KV, Steeds RP, Slater K, Rogers JK, Gkoutos GV, Kotecha D. A practical guide to assess the reproducibility of echocardiographic measurements. J Am Soc Echocardiogr. 2019;32(12):1505–15. Epub 2019 Oct 22. PMID: 31653530.

    Article  PubMed  Google Scholar 

  5. Beyls C, Hermida A, Bohbot Y, et al. Automated left atrial strain analysis for predicting atrial fibrillation in severe COVID-19 pneumonia: a prospective study. Ann Intensive Care. 2021;11:168. https://doi.org/10.1186/s13613-021-00955-w.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  6. Wang Y, Li Z, Fei H, et al. Left atrial strain reproducibility using vendor-dependent and vendor-independent software. Cardiovasc Ultrasound. 2019;17:9. https://doi.org/10.1186/s12947-019-0158-y.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

MC and FB has drafted the work, and FB, CL, SG, PM and AMD have substantively revised it. All authors read and approved the final manuscript.

Corresponding author

Correspondence to François Bagate.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Cicetti, M., Bagate, F., Lapenta, C. et al. Authors’ reply to “Left atrial strain: an operator and software-dependent tool”. Ann. Intensive Care 14, 124 (2024). https://doi.org/10.1186/s13613-024-01332-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13613-024-01332-z